Micah Roschelle

EECS Department, University of California, Berkeley

Technical Report No. UCB/

May 1, 2026

This report is delayed

Although cancer immunotherapy has become a cornerstone of oncology, most patients fail to respond to treatment. For these non-responders, early identification of resistance mechanisms is critical for effective second-line interventions. However, current clinical imaging is limited to a single biomarker with millimeter resolution at month-long intervals, rendering the dynamic interplay between cancer and the immune system largely opaque. 

Therefore, we present a miniaturized, implantable fluorescence imager designed for real-time monitoring of immune activity within a tumor. In this thesis, we take this idea from a concept to a bench-top demonstration of the full wireless system and, finally, to a fully packaged implant that we verify in mice. First, we describe an optical frontend design combining an interference filter with a fiber optic plate that enables fluorescent imaging of three biomarkers at 125-μm resolution without bulky lenses. Then, we introduce a wireless imaging chip, which harnesses ultrasound power harvesting and communication to achieve an operating depth of up to 5 cm in tissue. Finally, we present in vivo results using a wired implant with co-packaged waveguides and micro-laser diodes, tracking the CD8+ T cell response to immune checkpoint inhibitors over a week in tumor-bearing mice. Overall, these results represent significant progress toward a technology capable of providing rapid, real-time insight into therapeutic response and resistance to guide precision cancer immunotherapy.

Advisors: Ali Niknejad and Mekhail Anwar


BibTeX citation:

@phdthesis{Roschelle:32178,
    Author= {Roschelle, Micah},
    Editor= {Anwar, Mekhail and Niknejad, Ali and Muller, Rikky},
    Title= {An Implantable Fluorescence Imager for Monitoring Response to Cancer Immunotherapy},
    School= {EECS Department, University of California, Berkeley},
    Year= {2026},
    Month= {May},
    Number= {UCB/},
    Abstract= {Although cancer immunotherapy has become a cornerstone of oncology, most patients fail to respond to treatment. For these non-responders, early identification of resistance mechanisms is critical for effective second-line interventions. However, current clinical imaging is limited to a single biomarker with millimeter resolution at month-long intervals, rendering the dynamic interplay between cancer and the immune system largely opaque. 

Therefore, we present a miniaturized, implantable fluorescence imager designed for real-time monitoring of immune activity within a tumor. In this thesis, we take this idea from a concept to a bench-top demonstration of the full wireless system and, finally, to a fully packaged implant that we verify in mice. First, we describe an optical frontend design combining an interference filter with a fiber optic plate that enables fluorescent imaging of three biomarkers at 125-μm resolution without bulky lenses. Then, we introduce a wireless imaging chip, which harnesses ultrasound power harvesting and communication to achieve an operating depth of up to 5 cm in tissue. Finally, we present in vivo results using a wired implant with co-packaged waveguides and micro-laser diodes, tracking the CD8+ T cell response to immune checkpoint inhibitors over a week in tumor-bearing mice. Overall, these results represent significant progress toward a technology capable of providing rapid, real-time insight into therapeutic response and resistance to guide precision cancer immunotherapy.},
}

EndNote citation:

%0 Thesis
%A Roschelle, Micah 
%E Anwar, Mekhail 
%E Niknejad, Ali 
%E Muller, Rikky 
%T An Implantable Fluorescence Imager for Monitoring Response to Cancer Immunotherapy
%I EECS Department, University of California, Berkeley
%D 2026
%8 May 1
%@ UCB/
%F Roschelle:32178