Screen Printed MRI Receive Coils
Joseph Corea
EECS Department, University of California, Berkeley
Technical Report No. UCB/EECS-2018-147
December 1, 2018
http://www2.eecs.berkeley.edu/Pubs/TechRpts/2018/EECS-2018-147.pdf
The widespread use of MRI has created a demand for high quality images for current and emerging applications. High quality images are currently acquired by using application specific receive coils that fit close to the patient’s body to produce high signal to noise ratio. These coils are manufactured using traditional printed circuit board fabrication technologies that produce large heavy coils that do not suit some applications very well. In particular, two areas that have not been able to take advantage of the current receive coils are pediatric imaging and MR guided high intensity focused ultrasound therapy due to size, weight, and thickness constraints. These two areas would benefit greatly from the high quality imaging provided by purpose-built lightweight and thin receive coil arrays. One way to achieve a very lightweight and thin coil is to fabricate it from solution using printed electronics. Here for the first time, advances in solution-processed fabrication techniques have allowed lightweight, thin, and flexible receive coil arrays to be made for these applications. In this thesis the development of printed MRI receive coils is discussed, covering fabrication, characterization, and implementation. An entirely printed approach is used to create single element receive coils that are characterized and tested on 1.5 T and 3 T clinical systems. The materials used to fabricate the coil components are identified as a main avenue for improvement. A fully printed proof-of-concept array is made to demonstrate feasibility and is used to image a volunteer on a 3 T clinical system. Coils are optimized with components made from high quality flexible substrates to make better performing printed coils and arrays. These printed arrays are compared to commercially available arrays on several phantoms as well as on a volunteer on a 3 T scanner. In addition to creating coils for standard clinical imaging, several coils and arrays are optimized for use in an high intensity focused ultrasound interventional MRI. Coil materials are evaluated for acoustic transparency, stability in water, safety, and electrical quality. The optimized coils are used to evaluate image quality as well as to characterize the system level of acoustic transparency. An 8-channel coil array is used to characterize image quality on a volunteer. To show a system level proof-of-concept on an interventional MR system, optimized arrays are used to track ultrasonic heating inside phantoms and ex-vivo tissue. Overall, the characteristics of the printed coils described in this thesis enable a new generation of coils design for both traditional and emerging applications.
Advisors: Michael Lustig and Ana Claudia Arias
BibTeX citation:
@phdthesis{Corea:EECS-2018-147, Author= {Corea, Joseph}, Title= {Screen Printed MRI Receive Coils}, School= {EECS Department, University of California, Berkeley}, Year= {2018}, Month= {Dec}, Url= {http://www2.eecs.berkeley.edu/Pubs/TechRpts/2018/EECS-2018-147.html}, Number= {UCB/EECS-2018-147}, Abstract= {The widespread use of MRI has created a demand for high quality images for current and emerging applications. High quality images are currently acquired by using application specific receive coils that fit close to the patient’s body to produce high signal to noise ratio. These coils are manufactured using traditional printed circuit board fabrication technologies that produce large heavy coils that do not suit some applications very well. In particular, two areas that have not been able to take advantage of the current receive coils are pediatric imaging and MR guided high intensity focused ultrasound therapy due to size, weight, and thickness constraints. These two areas would benefit greatly from the high quality imaging provided by purpose-built lightweight and thin receive coil arrays. One way to achieve a very lightweight and thin coil is to fabricate it from solution using printed electronics. Here for the first time, advances in solution-processed fabrication techniques have allowed lightweight, thin, and flexible receive coil arrays to be made for these applications. In this thesis the development of printed MRI receive coils is discussed, covering fabrication, characterization, and implementation. An entirely printed approach is used to create single element receive coils that are characterized and tested on 1.5 T and 3 T clinical systems. The materials used to fabricate the coil components are identified as a main avenue for improvement. A fully printed proof-of-concept array is made to demonstrate feasibility and is used to image a volunteer on a 3 T clinical system. Coils are optimized with components made from high quality flexible substrates to make better performing printed coils and arrays. These printed arrays are compared to commercially available arrays on several phantoms as well as on a volunteer on a 3 T scanner. In addition to creating coils for standard clinical imaging, several coils and arrays are optimized for use in an high intensity focused ultrasound interventional MRI. Coil materials are evaluated for acoustic transparency, stability in water, safety, and electrical quality. The optimized coils are used to evaluate image quality as well as to characterize the system level of acoustic transparency. An 8-channel coil array is used to characterize image quality on a volunteer. To show a system level proof-of-concept on an interventional MR system, optimized arrays are used to track ultrasonic heating inside phantoms and ex-vivo tissue. Overall, the characteristics of the printed coils described in this thesis enable a new generation of coils design for both traditional and emerging applications.}, }
EndNote citation:
%0 Thesis %A Corea, Joseph %T Screen Printed MRI Receive Coils %I EECS Department, University of California, Berkeley %D 2018 %8 December 1 %@ UCB/EECS-2018-147 %U http://www2.eecs.berkeley.edu/Pubs/TechRpts/2018/EECS-2018-147.html %F Corea:EECS-2018-147